Files
Homelab-manager/server/drizzle/0054_green_beast.sql
T
bobbanandClaude Sonnet 5.5 232a5661ab A UPS in the map: read over NUT or SNMP, alerts, shutdown order
New UPS integration (NUT or SNMP v2c, read only). Monitoring -> UPS shows charge,
runtime, load and mains voltage with history and the times mains power was lost.
Mains lost and a nearly empty battery are critical alerts; battery to be replaced
and a heavy load are warnings. The UPS is a node in the dependency map and counts
as down while on battery, so servers that go offline with it are folded under its
alert; the page lists what is on it in the order to shut it down. /metrics series
and docs added.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
2026-10-21 21:47:31 +02:00

32 lines
1.1 KiB
SQL

CREATE TABLE `ups_readings` (
`id` integer PRIMARY KEY AUTOINCREMENT NOT NULL,
`integration_id` integer NOT NULL,
`at` text NOT NULL,
`charge` real,
`runtime_seconds` integer,
`load_percent` real,
`input_voltage` real,
`on_battery` integer DEFAULT false NOT NULL,
FOREIGN KEY (`integration_id`) REFERENCES `integrations`(`id`) ON UPDATE no action ON DELETE cascade
);
--> statement-breakpoint
CREATE INDEX `ups_readings_lookup_idx` ON `ups_readings` (`integration_id`,`at`);--> statement-breakpoint
CREATE TABLE `ups_state` (
`integration_id` integer PRIMARY KEY NOT NULL,
`model` text,
`manufacturer` text,
`status_text` text NOT NULL,
`on_battery` integer DEFAULT false NOT NULL,
`low_battery` integer DEFAULT false NOT NULL,
`replace_battery` integer DEFAULT false NOT NULL,
`overload` integer DEFAULT false NOT NULL,
`charge` real,
`runtime_seconds` integer,
`load_percent` real,
`input_voltage` real,
`output_voltage` real,
`on_battery_since` text,
`updated_at` text NOT NULL,
FOREIGN KEY (`integration_id`) REFERENCES `integrations`(`id`) ON UPDATE no action ON DELETE cascade
);