UniFi: servers plugged into switches; server page in sections; My work; settings search and undo

UniFi: the controller's client list is matched to servers by IP address, so a
server is connected through a switch or access point (and port). That is a
dependency made by itself, shown on the server page, the Network devices page
and the Connections map. IP Addresses can sync the devices' addresses.

A server's page is split into Overview, Health, Network, History, Tasks and
Settings, by ?view=; alerts link to the section they are about.

My work lists what has your name on it: alerts you have, maintenance you
started (extend, end with undo) and update runs you started, with a badge.

Settings has a search box (and the command palette lists every setting).
Removing a dependency, admin link, runbook, hand-made IP address, port opening
or restore test is undone from the message instead of asked about first.

Two backup tests used a fixed date and failed as days passed; they follow the
real clock now.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
This commit is contained in:
bobbanandClaude Sonnet 5.5 committed 2026-10-20 19:35:45 +02:00
1 parent 396e074108
commit 5e26e77340
45 files changed
+6224 -194

No files matched your search

+2
View File
@@ -241,6 +241,8 @@ the dashboard views themselves load fine. (UniFi only ever reads.)
others by hand (a server needs the switch it is plugged into).
- A device the controller has not seen online for longer than **Settings → Notifications → Alert when a network device is offline for** (10 minutes) is a critical **offline** alert about it. What needs it, and what
it is connected through if that is down too, is folded under it, like a guest under its host. It can be silenced with a maintenance window, and has runbooks like any target.
- **Servers plugged in:** the controller's list of what is connected is matched to servers by IP address (exact, and only when one server has that address). A server is then *connected through* the switch or access point
it is on — a dependency made by itself, shown on the server's page and on the Connections map. A key or account that may not read clients costs only this; devices, networks and Wi-Fi names are unaffected.
- If the controller cannot be read for twenty minutes its devices are neither raised nor cleared, and the Alerts page says it could not check; the integration itself is raised as failing like any other.
- **Not verified against a live controller** — built from Ubiquiti's published Integration API and the long-documented classic API (and tried against a pretend controller that answers the way those documents say),
but nobody has run it against real hardware yet. Every field is read defensively, so one a version renames is left blank rather than breaking the read. If a read fails or comes back empty, the **Diagnostic Log** has