Duplicati: know when a backup failed or has gone quiet
Duplicati reports each operation to a secret address (its own send-http-url option), so nothing calls Duplicati and no password for it is kept. Each machine is a source; each job is learned by name and shows its last result, duration, size, changes and a history. A failed run is a warning (critical from the second in a row); one that has not succeeded for longer than expected (per job, 2 days by default) is a warning, critical at three times that. Maintenance on the machine's server silences them; /metrics series added. Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
This commit is contained in:
1 parent
12f2662465
commit
2f082ca5c2
23 files changed
+8047
-4
No files matched your search
@@ -294,6 +294,8 @@ All gauges. The same table is checked by a test against what `/metrics` really s
|
||||
| `homelab_endpoint_certificate_days_left` | `name`, `kind` | Days until the certificate it shows expires (negative once it has). |
|
||||
| `homelab_service_level_target_percent` | `name`, `subject`, `type` | The availability a service-level target asks for. |
|
||||
| `homelab_service_level_availability_percent`, `homelab_service_level_error_budget_remaining_minutes` | `name`, `subject`, `type` | How available the thing has been so far this calendar month, and the downtime still allowed before the target is missed (negative once it is). Left out for a target with nothing recorded this month. |
|
||||
| `homelab_duplicati_backup_ok` | `backup`, `source` | 1 if the Duplicati backup's last run worked and it is not overdue, else 0. |
|
||||
| `homelab_duplicati_last_success_age_seconds`, `homelab_duplicati_source_size_bytes` | `backup`, `source` | Seconds since it last succeeded (a run with warnings counts), and the size of what its last report examined. |
|
||||
| `homelab_ups_on_battery` | `name` | 1 if the UPS has lost mains power and runs on its battery, else 0; left out for a UPS that has not been read in the last five minutes. |
|
||||
| `homelab_ups_battery_charge_percent`, `homelab_ups_runtime_seconds`, `homelab_ups_load_percent`, `homelab_ups_input_volts` | `name` | How full the battery is, how long it would last at the present load, how much of its capacity the load uses, and the mains voltage it sees — each left out when the UPS does not say. |
|
||||
| `homelab_heartbeat_up` | `name` | 1 if the job has reported in time and not said it failed, else 0; switched-off heartbeats are left out. |
|
||||
|
||||