A UPS in the map: read over NUT or SNMP, alerts, shutdown order

New UPS integration (NUT or SNMP v2c, read only). Monitoring -> UPS shows charge,
runtime, load and mains voltage with history and the times mains power was lost.
Mains lost and a nearly empty battery are critical alerts; battery to be replaced
and a heavy load are warnings. The UPS is a node in the dependency map and counts
as down while on battery, so servers that go offline with it are folded under its
alert; the page lists what is on it in the order to shut it down. /metrics series
and docs added.