A UPS in the map: read over NUT or SNMP, alerts, shutdown order

New UPS integration (NUT or SNMP v2c, read only). Monitoring -> UPS shows charge,
runtime, load and mains voltage with history and the times mains power was lost.
Mains lost and a nearly empty battery are critical alerts; battery to be replaced
and a heavy load are warnings. The UPS is a node in the dependency map and counts
as down while on battery, so servers that go offline with it are folded under its
alert; the page lists what is on it in the order to shut it down. /metrics series
and docs added.

Co-Authored-By: Claude Sonnet 5.5 <noreply@anthropic.com>
This commit is contained in:
bobbanandClaude Sonnet 5.5 committed 2026-10-21 21:47:31 +02:00
1 parent 3cb3e4988f
commit 232a5661ab
38 files changed
+8049 -16

No files matched your search

+2
View File
@@ -27,6 +27,7 @@ import { initFlapMonitor } from "./services/flapMonitor.js";
import { initSnoozeMonitor } from "./services/snoozeMonitor.js";
import { initUnifiSync } from "./services/unifiSync.js";
import { initHomeAssistantSync } from "./services/homeAssistantSync.js";
import { initUpsSync } from "./services/upsSync.js";
import { backfillMetricRollups } from "./services/serverMetrics.js";
import { backfillEndpointHourly } from "./services/endpointChecks.js";
import { initSelfBackupScheduler } from "./services/selfBackupScheduler.js";
@@ -75,6 +76,7 @@ initFlapMonitor();
initSnoozeMonitor();
initUnifiSync();
initHomeAssistantSync();
initUpsSync();
// The hourly and daily figures are built from what is already kept, once, the first time after they were added (in the background: nothing waits for it).
void Promise.all([backfillMetricRollups(), backfillEndpointHourly()]).catch((err) => console.error("[history] couldn't build the hourly and daily figures:", err));